Offices & commercial real estate

Per-floor and per-tenant scheduling. After-hours overrides routed through the supervisory application. Per-tenant energy attribution for billing or sustainability reporting. Common deployment shape: 5–30 floors, 40–200 indoor units, BACnet IP via OEM gateway.

Hotels & hospitality

Occupancy-aware setpoint policy. Room-by-room recovery ahead of check-in. Central ops view across properties. Reduce per-room HVAC operating cost without affecting guest comfort. Common deployment shape: 80–250 rooms, PMS integration optional.

Hospitals & healthcare

Zoned schedules for OPD, IPD, OT, and admin areas. Strict setpoint policy with tamper-resistant overrides. Full audit log for every change. Optional integration with existing BMS over BACnet IP. Critical-zone alarms routed to engineering.

Educational institutions

Term-based and examination-period schedules. Classroom-level zoning. Holiday lockouts with override windows for maintenance. Energy reporting aligned with sustainability programmes. Common deployment shape: 30–150 classrooms, often with multiple HVAC OEMs in mixed buildings.

Retail & food service

Trading-hours schedules with pre-open recovery. Centralised control across stores from a single supervisory console. Energy benchmarking per store and per region. Outlet-level alarm routing to maintenance partners.

Light industrial & warehousing

Process-area comfort and air handling. MODBUS RTU integration with PLCs where required. IP65 enclosure for plant-floor deployment. Galvanic and serial isolation suitable for high-noise electrical environments.

Deployment patterns

Common shapes by industry.

Indicative deployment shapes for each vertical. Site-specific scope is established during the survey stage.

Industry Typical size Zones Common OEM mix KPIs that matter
Offices & CRE5–30 floors40–200 indoor unitsDaikin, Mitsubishi, LGPer-tenant kWh, after-hours runtime, comfort complaints
Hotels & hospitality80–250 rooms1–2 per room + common areasDaikin, Hitachi, ToshibaPer-room kWh, pre-arrival recovery time, guest comfort
HealthcareMixed-use campus50–300 zones across OPD / IPD / OT / adminDaikin, Mitsubishi + chillersSetpoint-policy compliance, audit log integrity, critical-zone uptime
Educational30–150 classroomsPer-classroom or per-blockMixed: Daikin, LG, local OEMsTerm-period kWh, holiday-lockout adherence
Retail & F&B500–5,000 sq ft per outlet4–20 indoor units per outletDaikin, Toshiba, SamsungTrading-hours alignment, per-store kWh benchmark
Light industrialPlant + admin block10–80 zonesMixed; often MODBUS-onlyProcess-area comfort range, runtime hours, fault visibility
Engage AmbiAutomation

Send us a site brief.

If your building has multi-zone HVAC and exposes BACnet IP or MODBUS RTU — natively or via OEM gateway — AmbiAutomation can typically retrofit-automate it. Our engineering team will return a deployment shape within one business day.